Michael Anthony Homes
505 1/2 Germantown Pike, Lafayette Hill, PA 19444
800-898-0028

WARRANTY GUILDELINES

FRAMING


CATEGORY OBSERVATION ACTION REQUIRED BY BUILDER COMMENTS OR SUGGESTIONS
FRAMING
Ceiling
2.1   Uneven ceiling. Builder will correct if unevenness exceeds 3/8 inch within a 32 inch measurement. Some minor framing imperfections should be expected
Flooring 2.2 High and low areas. Builder will correct if high or low areas exceed 3/8 inch within a 32 inch measurement. Some minor framing imperfections should be expected.
2.3 Floor squeaks. No action required. A squeak-proof floor cannot be guaranteed. Lumber shrinkage as well as temperature and humidity changes may cause squeaks.
Roof 2.4 Split or warped rafters or trusses. No action required. Some splitting and warping is normal and is caused by high temperature effects on lumber.
Wall 2.5 Bow or bulge Builder will correct if bow or bulge exceeds 3/8 inch within 32 inch horizontal or vertical measurement. Minor framing imperfections should be expected.
2.6 Out-of-plumb. Builder will correct where out-of-plumb condition exceeds 1 inch within 8 ft. vertical measurement. Minor framing imperfections should be expected.
2.7 Wall is out-of-square. No action required. A wall out-of-square is not a Defect.

 


Return to Warranty Guidelines Directory

Caring for Your Home Directory

Montgomery County real estate

Home | Contact The Help Desk | Internet & Marketing Services